Inactive
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Notice ID:36C25225Q0061
Page 2 of 3 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market ...
Page 2 of 3 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Brand Name or Equal [Biodex - Sound Pro Combination Table] for VA Illiana Healthcare System, Danville, IL. General Requirements: All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. SAM Unique ID number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Lizbeth Bradett, at Lizbeth.Bradett@va.gov; no later than 3:30 PM (Central Standard Time), 28 October 2024. 36C25225Q0061 [Biodex - Sound Pro Combination Table] shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339113, Surgical Appliance and Supplies Manufacturing, is applicable to this acquisition; the size standard is 800 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided. Salient Characteristics: QTY 2 - 058-710 Sound Pro Combination Table, 115 Vac Overall: 71" l x 30" w (180.3 x 76.2 cm); 35" w (88.9 cm) with side rails Sonographer Cutout: 8" w x 14.75" l (20.3 x 37.4 cm) Adjustable sonographer cushion drops. Drop-Down Leg Section: 12.6" l (32 cm) Height Adjustable: 23" to 39" (58.4 to 99 cm) Fowler Back: 0° to 80° infinitely adjustable Controls: Hand Control: Activates height, Trendelenburg motions, Fowler positioning and auto level motions. Foot Control: Activates height, Trendelenburg motions and Fowler positioning. Wheels: 5" (12.7 cm) individual locking swivel casters; central floor-locking system Tabletop: Three primary sections: torso section features sonographer and patient cutouts with Mattress: Naugahyde®, antimicrobial mattress covers with advanced BeautyGard® provides protection against bacteria Patient Capacity: 500 lb (227 kg); weight Weight: 350 lb (159 kg) Power: 115 VAC OR 230 VAC Warranty: Two years parts and labor