J061 UPS and Battery Maintenance and Testing – Nashville VA Medical Center

Notice ID:36C249-27-AP-0670

The VA Network Contracting Office 9 is conducting market research for preventive and corrective maintenance and testing of existing Eaton 9390 UPS equipment and sealed VRLA batteries at the Nashville VA Medical Center, 1310 24th Avenue South, Nashville, TN 37212. The anticipated one-year scope includes one pre-site survey, one UPS preventive maintenance visit, three battery preventive maintenance visits, one load-bank test, 24/7 support, an eight-hour on-site emergency response, and a written report documenting test results, deficiencies, and recommended corrective actions. Interested firms should email the listed contact with company name, UEI, point of contact, business size under NAICS 811210, applicable SBA certifications including SDVOSB/VOSB, relevant Eaton 9390 experience, technician qualifications, ability to meet the eight-hour response requirement, and whether they would submit a quote. If applicable, firms should include their GSA Schedule contract number and SIN and identify any work outside the Schedule. No pricing is requested, no set-aside decision has been made, and this notice is not a solicitation or a commitment to award.

Department/Ind.Agency Subtier Office
VETERANS AFFAIRS, DEPARTMENT OF VETERANS AFFAIRS, DEPARTMENT OF 249-NETWORK CONTRACT OFFICE 9 (36C249)
  PSC   J061 MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
LOCATION: Not Given
Primary Contact
Shania Kimbrough
Not Given

Links (0)

Attachments (1)


Data sourced from SAM.gov. View Official Posting »

J061 UPS and Battery Maintenance and Testing – Nashville VA Medical Center

Notice ID:36C249-27-AP-0670

The VA Network Contracting Office 9 seeks capable sources for preventive and corrective maintenance and testing of existing Eaton 9390 UPS equipment and sealed VRLA batteries at the Nashville VA Medical Center, 1310 24th Avenue South, Nashville, TN 37212. The anticipated one-year scope includes one pre-site survey, one UPS preventive maintenance visit, three battery preventive maintenance visits, one load-bank test, 24/7 support, an eight-hour on-site emergency response, and a written report documenting test results, deficiencies, and recommended corrective actions. Interested firms should email shania.kimbrough@va.gov with company name, UEI, point of contact, business size under NAICS 811210, applicable SBA certifications such as SDVOSB/VOSB, relevant Eaton 9390 experience, technician qualifications, and ability to meet the eight-hour on-site response requirement. Firms should also indicate whether they would submit a quote if solicited and, if applicable, provide their GSA Schedule contract number and SIN and identify any work outside the Schedule. This notice is for market research only, not a solicitation or commitment to award; no pricing is requested and no set-aside decision has been made.

Department/Ind.Agency Subtier Office
VETERANS AFFAIRS, DEPARTMENT OF VETERANS AFFAIRS, DEPARTMENT OF 249-NETWORK CONTRACT OFFICE 9 (36C249)
  PSC   J061 MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
LOCATION: Not Given
Primary Contact
Shania Kimbrough
Not Given

Links (0)

Attachments (1)


Data sourced from SAM.gov. View Official Posting »