FY27 GNV Rebuild Cooling Towers

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Notice ID:36C24827Q0023

The Department of Veterans Affairs seeks a contractor to repair and replace cooling tower components and associated equipment at the Malcolm Randall VA Medical Center in Gainesville, FL. Work covers a BAC Cooling Tower Model 3728A with three cells and an EVAPCO Cooling Tower Model CTSN 8 351974 with six cells. The contractor must procure and deliver replacement components, install new drift eliminators, panels, motors, belts, sheaves, shaft assemblies, fill media, and framed louvers, and restore both towers to full manufacturer operating specifications. Responsibilities include removing defective components, verifying proper operation of each cell, ensuring safe access, and disposing of removed components off-site. All additional parts, materials, and equipment needed to meet manufacturer specifications must be furnished by the contractor.

Department/Ind.Agency Subtier Office
VETERANS AFFAIRS, DEPARTMENT OF VETERANS AFFAIRS, DEPARTMENT OF 248-NETWORK CONTRACT OFFICE 8 (36C248)
  PSC   J041 MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
LOCATION: Not Given
Primary Contact
Jeremy Parrish
352-***-9220

Links (0)

Attachments (1)


Data sourced from SAM.gov. View Official Posting »

FY27 GNV Rebuild Cooling Towers

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Notice ID:36C24827Q0023

The Department of Veterans Affairs seeks a contractor to repair and replace cooling tower components and associated equipment at the Malcolm Randall VA Medical Center in Gainesville, FL. The work covers BAC Cooling Tower Model BAC 3728A (three cells) and EVAPCO Cooling Tower Model CTSN 8 351974 (six cells), including removal of defective components, installation of new parts, and verification of proper operation. Required replacements include shaft assembly kits, fan assemblies, motors, belts, sheaves, sealer tape, fill media, drift eliminator kits, and framed louvers, with some OEM-specific items. The contractor must procure and deliver all listed materials, furnish any additional parts needed to meet manufacturer specifications, dispose of removed components off-site, and ensure safe access to louvers and other service areas. All work must account for equipment degradation, environmental conditions, and safe accessibility while restoring the cooling towers to full operational condition.

Department/Ind.Agency Subtier Office
VETERANS AFFAIRS, DEPARTMENT OF VETERANS AFFAIRS, DEPARTMENT OF 248-NETWORK CONTRACT OFFICE 8 (36C248)
  PSC   J041 MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
LOCATION: Not Given
Primary Contact
Jeremy Parrish
352-***-9220

Links (0)

Attachments (1)


Data sourced from SAM.gov. View Official Posting »