Inactive
Notice ID:36C24223Q1030
The VHA, VISN 2, VA Finger Lakes Healthcare Systems requires a contractor to provide medical gases for each of the three (3) VA medical center facilities, their respective clinics, and off-site locati...
The VHA, VISN 2, VA Finger Lakes Healthcare Systems requires a contractor to provide medical gases for each of the three (3) VA medical center facilities, their respective clinics, and off-site locations located in their region. The Contractor shall be responsible for providing, filling, transporting, handling, servicing, maintaining, delivering, picking up and storing medical gases and cylinders for all facilities located within VISN 2, VA Finger Lakes Healthcare System. All equipment and materials required to perform on the contract shall be provided by the Contractor (other than government-furnished property). Canandaigua VA Medical Center, 400 Fort Hill Road, Canandaigua, NY 14424 Size E Tanks 24 Cubic Foot-Leased tanks, must be Oxytote or equivalent, Qty 120 Bldg. 8 rm. 3. Estimated annual usage is 300 refills annually. Twice weekly delivery Size D-Tanks Oxygen 15 Cubic Foot-Leased tanks, Qty 18, Bldg. 8 rm. 3. Estimated annual usage 30 refills. Twice weekly delivery Size B Tank 6 Cubic Foot-Leased tanks Oxygen, Qty 8, Bldg. 8 rm. 3. Estimated annual usage is 20 refills. Twice weekly delivery. Size H Carbon Dioxide tanks, 50lb, leased tanks, Qty 2 (Dry ice production) Canandaigua Lab, Bldg. 38. Estimated annual usage 30 refills. Delivery on demand. Size H/K tanks 247 Cubic Foot -Leased tanks Oxygen-Qty 16, Bldg. 2 tank farm, estimated annual usage 50 refills. Twice weekly delivery. Calibration Gas size E tank 24 Cubic Foot, leased tank. .3% CO, .3% CH4, 21% O2. Qty 2, Bldg. 8 rm 3. Estimated annual usage 12 refills. Delivery on demand. Rochester Outpatient Clinic (ROPC), 260 Calkins Road, Rochester, NY 14620 Size H/K tanks 247 Cubic Foot -Leased tanks-Qty 8, med gas storage room in rear of facility, estimated annual usage 50 refills. Weekly delivery Size E Tanks 24 Cubic Foot-Leased tanks must be Oxytote or equivalent Qty 15, Med gas storage room in read of facility. Estimated annual usage is 30 refills. Weekly Delivery Calibration Gas size E tank 24 Cubic Foot, leased tank. .3% CO, .3% CH4, 21% O2. Qty 2, med gas storage room in rear of facility. Estimated annual usage 12 refills. Delivery on demand. Liquid Nitrogen Dewer-18 Liter, VA owned-Qty 1- Dermatology clinic, approximate annual usage is 24 refills a year. Weekly Delivery. Clinton Crossing (CCX) no gas required at this time but might be in the future. Size D Tanks are the only Tanks owned by the VA. All other Tanks are owned by Haun Specialty Gases Inc. Current Contract Number 36C24219D0001