6625--Fluke Networks DSX2-8000QI for the Northport VAMC
TITLE: 38-Sources Sought Notice SOL: 36C24222Q1024 DUE: 08/1/2022 at 16:00 EST NAICS: 334515 AGENCY: Department of Veterans Affairs, Northport VA Medical Center 79 Middleville Road Northport, NY 11768... TITLE: 38-Sources Sought Notice SOL: 36C24222Q1024 DUE: 08/1/2022 at 16:00 EST NAICS: 334515 AGENCY: Department of Veterans Affairs, Northport VA Medical Center 79 Middleville Road Northport, NY 11768. POC: Jonatan Rondon Email all responses only to: Jonatan.rondon@va.gov DESCRIPTION: This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of all businesses relative to the North American Industry Classification Code (NAICS) 334515. The Department of Veteran s Affairs is seeking all qualified business manufacturer or distributors of small business manufacturers to all the following specifications: Requirement: The Northport VA Medical Center Engineering department is looking to acquire the new Fluke Networks DSX2-8000QI by TEquipment, this is the preferred equipment as engineering staff has deemed it the right equipment for their hospital s need. However, the Service will accept Brand Name or equal based on the desired characteristics and specifications below. Contractor is to provide the following: Fluke Networks DSX2-8000QI Versiv 2 CableAnalyzer w/Quad OLTS and Fiber Inspection, Integrated Wi-Fi Versiv modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards ProjX system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly Taptive user interface simplifies set-up, and eliminates errors Analyze test results and create professional test reports using LinkWare management software Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting Intertek Verified to TIA Level 2G the most stringent accuracy requirement Complete testing for your Industrial Ethernet copper cabling Specifications: DSX2-8000 Performance Specifications Category 8 test modes (or lower link categories) ANSI/TIA-1152 Level 2G Class I/II test modes Proposed standard IEC 61935-1 Ed. 5 Level VI Length of Twisted Pair Cabling1 Without Remote With Remote Range 800 m (2600 ft) 150 m (490 ft) Resolution 0.1 m or 1 ft 0.1 m or 1 ft Accuracy ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 2 %) ± (0.3 m + 4 %); 150 m to 800 m Propagation Delay Without Remote With Remote Range 4000 ns 750 ns Resolution 1 ns 1 ns Accuracy ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 2 %) ± (2 ns + 4 %); 750 ns to 4000 ns Delay Skew Range 0 ns to 100 ns Resolution 1 ns Accuracy ± 10 ns DC Loop Resistance Test Range 0 to 540 Resolution 0.1 Accuracy ± (1 + 1 %) Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications Power Meter Specifications Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional) Detector Type InGaAs Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) Power Measurement Uncertainty1,2 < +/- 5% +/- 32 pW Measurement Linearity3 < ± 0.1 dB Re-calibration Period 1 year 1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 W (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 m and NA = 0.14 for 9/125 m. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up. Loss/Length Specifications Specification CertiFiber Pro Multimode Modules CertiFiber Pro Singlemode Modules Testing Speeds (excludes referencing times) Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: 2 seconds (2 wavelengths, one direction auto wavelength detection) Input/Output Connectors Interchangeable connector adapter (LC standard, SC, ST and FC optional) Launch Condition1,2 Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 Fiber Types Tested 50/125 µm or 62.5/125 µm singlemode Source Type and Wavelengths LED source 850 nm ± 30 nm 1300 nm ± 20 nm Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm Maximum Length Measurement 12 km 130 km Length Measurement Accuracy ± 1.5 m plus ± 1 % of length ± 1.5 m plus ± 1 % of length Output Power (Nominal) -24 dBm with EF-TRC -4 dBm Output Power Stability3 ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes ± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes 1. At the output of the EF-TRC 2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor 3. Relative to power level after 15 minute warm up at constant temperature Loss/Length Specifications (continued) Source Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) Power Measurement Uncertainty1, 2 < +/- 5% +/- 32 pW Measurement Linearity3 < ± 0.1 dB Re-calibration Period 1 year 1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 W (-10 dBm), continuous wave (CW) for absolute power at 850 Selected Specifications Visual Fault Locator (VFL) Title Requirement Output Power >-5 dBm <0 dBm SMF-28 singlemode fiber Continuous wave SC/UPC connector Operating Wavelength 650 nm nominal Output Modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency) Connector Adapter 2.5 mm universal Laser Safety Class II CDRH Over operating temperature range Environmental Specifications Title Requirement Operating Temperature -18° C to 45° C Storage Temperature -30° C to +60° C Operating Relative Humidity 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) % RH without condensation 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) Vibration Random, 2 g, 5 Hz-500 Hz Shock 1 m drop test with and without module and adapters Safety CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2 Pollution Degree 2 Altitude Operating: 4,000 m; storage: 12,000 m EMC EN 61326 1 THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 334515 (Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals). Response Email should contain the following information: Name of firm, Socio-Economic category of the firm, complete address, phone & fax number of contacts.
Links ()
Attachments ()
Data sourced from SAM.gov.
View Official Posting »