RDD/POP: 12 May 2025 Delivery address and ATTN to: LTJG Christian Burzycki SFLC LRE PL UNITED STATES COAST GUARD BASE CHARLESTON 1050 Register St North Charleston, SC 29405-2421 see attached SOW also ...
RDD/POP: 12 May 2025 Delivery address and ATTN to: LTJG Christian Burzycki SFLC LRE PL UNITED STATES COAST GUARD BASE CHARLESTON 1050 Register St North Charleston, SC 29405-2421 see attached SOW also repeated below. 01-51-1, STBD QAWTD: Exterior Door Door on FWD part of hangar, to STBD Boat Deck FR 51 Cutout size: 33” x 73” x 11.5” Sill cut: 5.5” Sill height: 9” Clear opening: 26” x 66” x 8” Gasket: Silicon rubber Fed Spec ZZ-R-765 (exterior) Material: Steel Fixed Light: Yes, 6” diameter, round Deadlight/fixed light cover: Yes, installed on stiffener side of door Hold back hook: Yes Hasp and staple: No Latch: No CPS latch Swing: LH Dogs: 10 Design Pressure: 15 psi (tightness pressure) Finish: Flame sprayed aluminum and formula 150 primer Reference: NAVSEA DWG 803-6397268 rev B Assy #25-E 01-52-2, PORT QAWTD: Exterior Door Door on FWD part of hangar, to PORT FAS Deck FR 52 Cutout size: 33” x 73” x 11.5” Sill cut: 5.5” Sill height: 9” Clear opening: 26” x 66” x 8” Gasket: Silicon rubber Fed Spec ZZ-R-765 (exterior) Material: Steel Fixed Light: Yes, 6” diameter, round Deadlight/fixed light cover: Yes, installed on stiffener side of door Hold back hook: Yes Hasp and staple: No Latch: No CPS latch Swing: LH Dogs: 10 Design Pressure: 15 psi (tightness pressure) Finish: Flame sprayed aluminum and formula 150 primer Reference: NAVSEA DWG 803-6397268 rev B Assy #26-E