The Contractor shall crop and renew up to 12 linear feet of starboard and port fuel deck riser piping from the flange on the Main Deck riser through-deck fitting to the first coupling in the Engine Ro...
The Contractor shall crop and renew up to 12 linear feet of starboard and port fuel deck riser piping from the flange on the Main Deck riser through-deck fitting to the first coupling in the Engine Room (approximately Frame 109), including associated fittings, as designated by the Coast Guard Inspector and as shown on Coast Guard Drawing 618 WMEC 261-001. Piping to be renewed is 2-1/2 inch Sched 40 steel, including 90 degree elbows and deck penetrations, and gate valves on both port and starboard sides, as designated by the Coast Guard Inspector and as shown on Coast Guard Drawing 618 WMEC 261-002, Sheet 4, Elevation ā22-Gā and in accordance with Bill of Materials No. 13.