Total Small Business Set-Aside (FAR 19.5)
Notice ID:30184PR230000022
This solicitation has been extended until the 28th of April as the SOW has been updated. please scroll down to see questions asked by a contractor and the answers given. To procure and replace VMAG sl...
This solicitation has been extended until the 28th of April as the SOW has been updated. please scroll down to see questions asked by a contractor and the answers given. To procure and replace VMAG slide gate panel, trolleys and VMAG hardware for a reliable sliding gate system.. - Remove current steel gate and install one 22ft aluminum slide gate, similar style w/ curved picket top. - Gate to include chainlink infill on entire gate length - Gate to be installed on existing posts (modify hardware as needed) - Modify post and catch at end of the gate to stabilize gate when closed. - Replace two (2) gate trolleys, - Replace or repair damaged support channel - Reinstall rail using two (2) VMAG hardware kits - replace gate bump stops as required. - Wire and test proper operation - To perform start-up of unit upon job completion and observe proper operations of gate as per manufacturers guidelines. - Install parts listed above - To offer 1 year warranty on services provided. Location of Service: USCG Station Atlantic City 900 Beach Thorofare Atlantic City, NJ 08401 For site visits please contact: POC at Unit: MKC Hawley, Douglas (douglas.e.hawley@uscg.mil) or MK1 Kohl, Robert (robert.j.kohl@uscg.mil) Phone: (609) 344-6595 Questions and Answers; Questions: We have some additional RFI's Questions for the subject project. A normal commercial slide gate opener (recommend a lift master csl24ul slide gate operator) would be acceptable, please confirm. As per our vendor's suggestion, they would like some type of wireless means of control from inside the building. Our vendor recommends a wired 3-button station and a wireless transmitter for inside the building. 2. Please confirm that if we can re-use the existing key pad and phone access system. Answers: Yes a normal commercial slide gate opener would be fine as long as it is accessible for entry from outside the gate at the key pad, from inside our watch room in the main building and preferably the phone system here in case we aren’t at the main button area. If the vendor can use the prewiring for the existing keypad outside the main gate and it will work yes lets do it. I’m trying to address a few concerns only here with the gate. If it is vmag or not doesn’t matter to me. Gate reliability (being able to withstand the weather here with winds reaching 40-60 mph on rare occasions. // not so technical that it it out of our repairing abilities. // Designed to evenly distribute weight while opening and closing. Gate accessibility ( being able to operate the gate from keypad/watch room/station phone.) And lastly deterring people from trying to come in. ( top of gate deterring people from climbing // little to no clearance while closed on sides and underneath. THank you.