Automated Liquid Handling Platform

Inactive
Notice ID:75F40126Q00423

The procurement requires a newly manufactured benchtop automated liquid handling platform; used, refurbished, reconditioned, remanufactured, or demonstration equipment is not acceptable. The desired system must be user-friendly, easy to clean, space- and energy-saving, capable of fast automatic pipetting of multiple solutions and serial dilutions across or down 96- or 384-well plates, with interchangeable well formats, variable volumes, selectable rows/columns/wells, customizable protocols, programmable temperatures, and compatibility with the specified containment enclosure. Market research identifies only the Agilent Technologies Bravo Automated Liquid Handling Platform as meeting the minimum needs, including operation within a 46in W x 24in D x 30in H biosafety cabinet supporting 120 lbs without disrupting airflow. Minimum technical requirements include interchangeable 96-channel or 384-channel pipetting heads with independent tip pickup, at least a 15-position deck, 0.1–200 microliter dispensing with no worse than 5% deviation, and later configurability for shaking, heating, cooling, and filtration. The platform must include a controller/software for custom protocols and a dedicated computer, be compatible with standard 96- and 384-well microplates, operate at 5–40°C and 10–90% non-condensing relative humidity, require no deck or plate temperature-control range, and comply with applicable Federal, state, and local safety standards.

Department/Ind.Agency Subtier Office
HEALTH AND HUMAN SERVICES, DEPARTMENT OF FOOD AND DRUG ADMINISTRATION FDA OFFICE OF ACQ GRANT SVCS
  PSC   LABORATORY EQUIPMENT AND SUPPLIES
LOCATION: Not Given
Primary Contact
Reagan Davis
301-***-0910

Links (0)

Attachments (0)


Data sourced from SAM.gov. View Official Posting »

Automated Liquid Handling Platform

Notice ID:75F40126Q00423

The government seeks a newly manufactured benchtop automated liquid handling platform that is not used, refurbished, reconditioned, remanufactured, or previously used for demonstration. Based on agency research, only the Agilent Technologies Bravo Automated Liquid Handling Platform meets the minimum needs, as other machines do not dispense low volumes or fit within a biosafety cabinet. The platform must fit and operate within a 46in W x 24in D x 30in H biosafety cabinet supporting 120 lbs without disrupting airflow, perform serial dilutions across or down 96- or 384-well plates, use interchangeable 96-/384-channel pipetting heads with independent tip pickup, provide at least 15 deck positions, and dispense 0.1 to 200 microliters with =5% deviation. It must be customizable, support later shaker/heater/cooler/filtration configurations, include a controller, software, and dedicated computer, be compatible with standard microplates, and operate at 5 to 40°C and 10 to 90% non-condensing humidity. Compliance with applicable Federal, state, and local safety standards is required.

Department/Ind.Agency Subtier Office
HEALTH AND HUMAN SERVICES, DEPARTMENT OF FOOD AND DRUG ADMINISTRATION FDA OFFICE OF ACQ GRANT SVCS
  PSC   6640 LABORATORY EQUIPMENT AND SUPPLIES
LOCATION: Not Given
Primary Contact
Reagan Davis
301-***-0910

Links (0)

Attachments (0)


Data sourced from SAM.gov. View Official Posting »

Automated Liquid Handling Platform

Inactive
Notice ID:75F40126Q00423

This requirements is for the acquisition of one (1) automated liquid handling platform, including the dedicated control computer, adaptors, and attachments, the manufacturer's standard commercial warr...

Department/Ind.Agency Subtier Office
HEALTH AND HUMAN SERVICES, DEPARTMENT OF FOOD AND DRUG ADMINISTRATION FDA OFFICE OF ACQ GRANT SVCS
  PSC   LABORATORY EQUIPMENT AND SUPPLIES
LOCATION:

Links ()

Attachments ()


Data sourced from SAM.gov. View Official Posting »