Inactive
Notice ID:RFP354026_BLN
FERMILAB REQUIRES YOUR FIRM FIXED PRICE QUOTE FOR THE FOLLOWING: 1 EACH: MASS FLOW CONTROLLER (BROOKS INSTRUMENT GF040CXXC-SA40010CVXPBS4- XXXXAX-70F OR EQUIVALENT) • MultiFlo Configurable • Standard ...
FERMILAB REQUIRES YOUR FIRM FIXED PRICE QUOTE FOR THE FOLLOWING: 1 EACH: MASS FLOW CONTROLLER (BROOKS INSTRUMENT GF040CXXC-SA40010CVXPBS4- XXXXAX-70F OR EQUIVALENT) • MultiFlo Configurable • Standard Application • Normally Closed Valve • 0.2 - 10 SCCM Flow Range, N2, Bin Size SA40 • 1/4" VCR Process Connections • Positive Downstream Pressure • Buna Orings and Buna Valve Seat • 15 Pin D-Connector, 4-20mA Input/Output, +24 VDC Power Input, RS485 • Auto Shut Off • 70F Calibration Reference Temperature 1 EACH: MASS FLOW CONTROLLER (BROOKS INSTRUMENT GF040CXXC-SA40010CVXPNS4- XXXXAX-70F OR EQUIVALENT) • MultiFlo Configurable • Standard Application • Normally Closed Valve • 0.2 - 10 SCCM Flow Range, N2, Bin Size SA40 • 1/4" VCR Process Connections • Positive Downstream Pressure • Neoprene Orings and Neoprene Valve Seat • 15 Pin D-Connector, 4-20mA Input/Output, +24 VDC Power Input, RS485 • Auto Shut Off • 70F Calibration Reference Temperature 1 EACH: MASS FLOW CONTROLLER (BROOKS INSTRUMENT GF040CXXC-SA42092C-VXPNS4-XXXXAX-70F OR EQUIVALENT) • MultiFlo Configurable • Standard Application • Normally Closed Valve • 1.84 - 92 SCCM Flow Range, N2, Bin Size SA42 • 1/4" VCR Process Connections • Positive Downstream Pressure • Neoprene Orings and Neoprene Valve Seat • 15 Pin D-Connector, 4-20mA Input/Output, +24 VDC Power Input, RS485 • Auto Shut Off • 70F Calibration Reference Temperature 1 EACH: MASS FLOW CONTROLLER (BROOKS INSTRUMENT GF040CXXC-SA41030C-VXPES4-XXXXAX-70F OR EQUIVALENT) • MultiFlo Configurable • Standard Application • Normally Closed Valve • 0.6 - 30 SCCM Flow Range, N2, Bin Size SA41 • 1/4" VCR Process Connections • Positive Downstream Pressure • EPDM Orings and EPDM Valve Seat • 15 Pin D-Connector, 4-20mA Input/Output, +24 VDC Power Input, RS485 • Auto Shut Off • 70F Calibration Reference Temperature 1 EACH: POWER SUPPLY, READ OUT, CONTROL UNIT (BROOKS INSTRUMENT (0254AA1B13A OR EQUIVALENT) • 4 Channels • Panel Mount Model • Power Cord for 120 VAC Input (wall plug) • +24 VDC Output Power (to MFC's) • Current Pinout (4-20mA I/O Signal) • RS-232 Communication Cable 4 EACH: MASS FLOW CABLE (BROOKS INSTRUMENT 124Y058AAA OR EQUIVALENT) •10 Feet •D-Connector on One End •D-Connector on Other End 1 EACH: MULTFLOW CABLE KIT (BROOKS INSTRUMENT 778Z010ZZZ OR EQUIVALENT) • USB to 2.5mm Cable Assembly • Software ALL OFFERS MUST INCLUDE COMPLETED SARC AND PUR466.