Inactive
Notice ID:323058
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal p...
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions. SLAC has a requirement for a U.S. domestic end item source of the following product: (1) Quantity: 1 each Unipolar Pulse Generator Model FPG 20-01PM3 (mfg: FID GmbH) Maximum amplitude into 50 Ohm -- 20 kV Amplitude adjustment range - 3 kV to 20 kV Polarity -- Positive, fixed in production Pulse shape - Trapezoidal Rise time (10-90% V)- 0.5 ns or less (fixed) Pulse duration at 95% V -- 3.5 +/- 0.5 ns (fixed) Fall time (90-10% V)- not more than 1-1.5 ns (fixed)* Flat top tolerance -- +/- 1 % V over central 2.0 ns of pulse duration period Pulse-to-pulse amplitude repeatability - +/- 1-1.5% V Pre-pulse amplitude within 10 ns of start of pulse -- less than 2% V Pulse-to-pulse jitter (determined at 50% V)- 35 ps RMS, max Maximum PRF -- 120 Hz, adjustable Oto 120 Hz Triggering - Internal; and External by 5V @50 Ohm, rise time 5-10 ns, duration 100-1000 ns Trigger-to-output pulse delay - Less than 200 ns Digital display & control block Remote control - of all adjustable parameters via RS232 serial port Output connector - HN female Input power -- 100-240 V AC, 50 or 60 Hz (2) Quantity 1 each ATF 20L50-P20/10M-B1000-D40 High Voltage Attenuator Maximum input voltage - 20 kV Input impedance - 50 Ohm Input connector- HN Output impedance - 50 Ohm Output connector - N-type female Bandwidth - DC-1000 MHz Max peak power - 10 MW Maximum average input power - 20 W Division ratio - not less than 40 dB Size - approximately 300 x 200 x 50 mm The award will be made based upon the Lowest Price Technically Acceptable method. Marking of Proprietary/Confidential Information. Offerors shall properly mark and identify with a restrictive legend or information markings on pages of the proposal that contain Proprietary/confidential information. For Offeror to be eligible for a subcontract award with the University and the U.S. Department of Energy (DOE), Offeror shall be registered with the System for Award Management (SAM). Entities may register at no cost directly at the SAM website: https://www.sam.gov. The resulting purchase order shall be performed in accordance with SLAC National Accelerator Laboratory's Terms and Conditions for Fixed Price Commercial Supplies and Services dated December 2016 NOTE: The following documents are attached in this solicitation. Buy American Act Certificate Representations & Certification Rider Terms & Conditions for Fixed Price Commercial Supplies and Services, December 2016