Inactive
Notice ID:3-B185-Q-00713-00
Argonne National Laboratory is looking to source a 2D Transfer System with Trinocular Microscope. Please see specifications below. 2D Transfer System with Trinocular Microscope 1. Base plate 2. Trinoc...
Argonne National Laboratory is looking to source a 2D Transfer System with Trinocular Microscope. Please see specifications below. 2D Transfer System with Trinocular Microscope 1. Base plate 2. Trinocular Microscope with motorized Z focusing stage (1 set) Optical system = Infinity corrected Observation Method = Brightfield Illumination = Reflected (Co-axial or epi-scopic and two flexible arm LEDs) Illumination system = High bright white LEDs, Intensity adjustable. Nosepiece = Manual, revolving, quadruple with positive precision click stops Viewing head = Siedentopf Trinocular head, 30 degree, 48-75mm IP adjustment Eyepiece= 10X Wide field eyepiece, FN = 20mm, dioptre adjustable. Focusing = Motorized with Push button as well as software controls. Microscope Objectives = LWD Plan Apo 5X NA = 0.14 WD = 40mm FOVeyepiece = 4mm FOVcamera = 1.14mm x 0.856mm RMS objective adapter = 2 Nos. Camera specifications:- Optical format = 1/2.5” CMOS Active imager size = 5.70mm x 4.28mm Active pixels = 2592 x 1944 (5Mp) Pixel size = 2.2 x 2.2 um Shutter type = Electronic rolling shutter(ERS) Frame rate = Full resolution – 7 fps, 640*480(BIN) – 26.7 fps Spectral response = 380-650nm Exposure time = 0.072ms – 3000ms Image format = RAW, BMP, JPG, PNG Operating temperature = -30oC to +70oC Sensitivity = 1.76V/lux-sec(550nm) Power consumption = 381mW at 15 fps full resolution Interface = USB2.0 Lens mount = C-mount 3. XYZ theta sample stage with heater & Vacuum chuck (1 set) Motorized rotation stage Top plate diameter -75mm M6 tapped holes at 12.5mm grid, 360degree rotatable Precision worm gears Double bearing design Resolution = 0.01 degree Accuracy = 0.01 degree with encoder Drive = Stepper motor Black anodized aluminium Motorized XYZ stage XYZ Travel=25mm each XYZ drive = Precision lead screw with stepper motor Leadscrew pitch = 0.4mm XYZ Resolution = 7.8nm (micro step mode) XYZ axis accuracy = 1 microns with linear encoder. Guide way = Precision V grooved guide way Construction = Aluminium alloy Finish = Black anodized Software controls for XYZ sample stage. Joy stick controls for XY and Push buttons for Z axis. Vacuum chuck and Heater with temperature controller Sample plate diameter = 40mm Temperature range = RT – 200oC Temperature increment = 1 degree C PID Controller Vacuum provision to hold the samples Vacuum Pump Software controls for temperature and vacuum. 4. Motorized XYZ Stamping stage with manual tilting platform (1set): - XYZ Travel=25mm each XYZ drive = Precision lead screw with stepper motor Leadscrew pitch = 0.4mm XYZ Resolution = 7.8nm (micro step mode) XYZ axis accuracy = 1 microns with linear encoder. Guide way = Precision V grooved guide way Construction = Aluminium alloy Finish = Black anodized Software controls for XYZ stage Joy stick controls for XY Push buttons for Z axis. Tilting platform drive = leadscrew, manual Construction = Aluminium alloy Finish = Black anodized Glass /sample Holder 5. Image grabbing &motorized controlled software Optional Accessories - LWD Plan Apo 10X Microscope objective NA=30 Working Distance = 34mm FOV eyepiece = 2mm FOV camera = 0.57mmx0.428mm If able to provide items or a similar item, please complete, provide, and address the below. Proposal Lead Time Country of Origin ANL-70 - Please sign on page 1