Inactive
Total Small Business Set-Aside (FAR 19.5)
Notice ID:SPMYM125Q0137
The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY) intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically Acceptable (LPTA) Evalu...
The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY) intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart 12.6, as supplemented with the additional information included in this notice. The Contract Line Item (CLIN) is as follows: ITEM NO. DESCRIPTION QTY U/I UNIT PRICE TOTAL 0001 FLUKE T5-1000 ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER MODEL#: FLUKE T5-H5-1AC II KIT REF P/N 2PY98 100 EA Determined by vendors Determined by vendors T5-600/T5-1000 Electrical Tester Parts and Service The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the TS-600/TS-1000 Electrical Tester Instruction Sheet. To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com. Specifications Accuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows: ::!;([ % of reading] + [number of least significant digits]) Temperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F) Serial Numbers 79560000 and Above General Specifications Calibration One-year calibration cycle. Maximum Voltage Between any Terminal and Earth Ground TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2 TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2 Maximum Voltage Between Current Fork and Earth Ground TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.) Temperature Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F) Altitude Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft) Relative Humidity O o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F); O o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F) Battery Type and Life AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride Shock, Vibration 1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1 1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum) Surge Protection TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010 Enclosure Rating IP 52 per IEC 60529, no vacuum applied General Specifications (continued) RF Field Specification 0.5 % full scale + (specified accuracy) at 3 V/m Safety Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995. EMC EN 61326 Certifications CE