Motor T Prefabricated Modular In-Plant Classroom
SWFPAC requires procurement and installation of one prefabricated modular in-plant classroom with an independent HVAC system inside the Motor Transport Building at Naval Base Kitsap – Bangor, 2106 Scorpion Avenue, Silverdale, WA. The classroom must be roughly 15 ft by 20 ft with a 9–12 ft ceiling, comply with ADA and fire/electrical codes, include a locking entrance door with partial window, 20-amp outlets on each wall, LED lighting at 300–500 lux, and at least two Cat-5e or better Ethernet ports per wall; the HVAC must maintain 65–75°F when outside conditions are 32–100°F. The contractor must deliver/install the classroom, secure it to the existing concrete slab, provide internal electrical and network connections plus external junction boxes, stamped engineered drawings with structural calculations, OEM maintenance guidance, operational testing, initial operator training, and three