X-Ray Computed Tomography Cabinet System (Revised Requirements)

Inactive
Notice ID:N00421-26-SIMACQ-AB21000-0011

The Naval Air Warfare Center intends to award a sole source contract for a large format X-ray Computed Tomography Cabinet System capable of scanning parts at least 36 inches in diameter and 96 inches in height, with two x-ray tubes (microfocus up to 225kV and another up to 450kV). The system must include a Varex 4343N digital detector array, acquisition and analysis computers with Volume Graphics VG Studio MAX software, on-site installation, training, and a one-year service maintenance contract. Performance will occur at Patuxent River, Maryland, with a two-year period of performance covering installation, testing, training, and one year of maintenance. No budget amount is specified. Interested parties must submit a capabilities statement by 2:00 p.m. EST on 29 April 2026.

Department/Ind.Agency Subtier Office
DEPT OF DEFENSE DEPT OF THE NAVY NAVAL AIR SYSTEMS COMMAND
  PSC   PHYSICAL PROPERTIES TESTING AND INSPECTION
LOCATION: Not Given
Primary Contact
Michael Lang
Not Given

Links (0)

Attachments (0)


Data sourced from SAM.gov. View Official Posting »

X-Ray Computed Tomography Cabinet System (Revised Requirements)

Inactive
Notice ID:N00421-26-SIMACQ-AB21000-0011

The Naval Air Warfare Center intends to award a sole-source contract for a large-format X-ray Computed Tomography Cabinet System with specific technical capabilities, including scanning parts up to 36” in diameter and 96” in height. The anticipated period of performance is two years, including installation, testing, training, and one year of service and maintenance. The work will be performed for the Non-destructive Inspection Branch in Patuxent River, Maryland. The contract type is anticipated to be a combination of Firm-Fixed-Price and Cost-Plus-Fixed-Fee. This is a market research notice to gauge interest and capability, and a competitive procurement may or may not result.

Department/Ind.Agency Subtier Office
DEPT OF DEFENSE DEPT OF THE NAVY NAVAL AIR SYSTEMS COMMAND
  PSC   PHYSICAL PROPERTIES TESTING AND INSPECTION
LOCATION: Not Given
Primary Contact
Michael Lang
Not Given

Links (0)

Attachments (0)


Data sourced from SAM.gov. View Official Posting »

X-ray Computed Tomography Cabinet System

Inactive
Notice ID:N00421-26-SIMACQ-AB21000-0011

The Naval Air Warfare Center intends to award a sole-source contract for a large-format X-ray Computed Tomography Cabinet System with specific technical capabilities, including dual x-ray tubes and specified detectors. The system requires on-site installation, verification, training, warranties, and a one-year service contract. The anticipated period of performance is two years, including installation, testing, and the service period. The work will be performed for the Non-destructive Inspection Branch in Patuxent River, Maryland. This is a sources-sought notice to gauge market capability and determine if a competitive procurement is warranted.

Department/Ind.Agency Subtier Office
DEPT OF DEFENSE DEPT OF THE NAVY NAVAL AIR SYSTEMS COMMAND
  PSC   6635 PHYSICAL PROPERTIES TESTING AND INSPECTION
LOCATION: Not Given
Primary Contact
Michael Lang
Not Given
Alt Contact
Jossie Washington
Not Given

Links (0)

Attachments (0)


Data sourced from SAM.gov. View Official Posting »

X-ray Computed Tomography Cabinet System

Notice ID:N00421-26-SIMACQ-AB21000-0011

The Naval Air Warfare Center intends to award a sole-source contract for a large-format X-ray Computed Tomography Cabinet System with specific technical capabilities, including scanning parts up to 800mm by 1415mm and dual x-ray tubes. The anticipated period of performance is two years, including installation, testing, training, and one year of service. The work will be performed for the Non-destructive Inspection Branch in Patuxent River, Maryland. The contract type is anticipated to be a combination of firm-fixed-price and cost-plus-fixed-fee. This is a sources-sought notice to identify capable firms, and a response is not required to be eligible for any future acquisition.

Department/Ind.Agency Subtier Office
DEPT OF DEFENSE DEPT OF THE NAVY NAVAL AIR SYSTEMS COMMAND
  PSC   6635 PHYSICAL PROPERTIES TESTING AND INSPECTION
LOCATION: Not Given
Primary Contact
Michael Lang
Not Given
Alt Contact
Jossie Washington
Not Given

Links (0)

Attachments (0)


Data sourced from SAM.gov. View Official Posting »