TRANSMITTER,PRESSUR
The requirement is for repair/upgrade, testing, inspection, and acceptance of a pressure transmitter (NSN 6685-01-579-6971, P/N 8TJ167GHW1) to Ready for Issue condition, with the contractor responsible for facilities, labor, materials, parts, and tooling unless Government-furnished. The contractor must maintain an ISO 9001/SAE AS9100 quality system, calibration per ANSI/NCSL Z540.3 or equivalent, configuration management, inspection records, MIL-STD-130 markings, MIL-STD 2073 packaging, and enclosed storage; MIL-W-81381 wire is prohibited. The identified repair source/location is AMETEK INC, 50 Fordham Rd, Wilmington, MA 01887. Required repair turnaround time is 118 days after asset receipt, and the induction expiration date is 365 days after contract award. A 12-month warranty applies, with a 60-day period after discovery of defect.