Inactive
Total Small Business Set-Aside (FAR 19.5)
Notice ID:N0017422SIMACQR30015
This is a full and open market Request For Quotation (RFQ). The RFQ for this procurement is N0017422SIMACQR30015. Your quote should include the RFQ number identified above, vendor's cage code, vendor'...
This is a full and open market Request For Quotation (RFQ). The RFQ for this procurement is N0017422SIMACQR30015. Your quote should include the RFQ number identified above, vendor's cage code, vendor's DUNS number, point of contact, phone number, shipping charges, all items shall be delivered FOB Destination. RFQ should be submitted NLT 16 Mar 2022. SALIENT CHARACTERISTICS FOR 3KV VARIABLE PULSERS: REQUIREMENTS: Naval Surface Warfare Center Indian Head Division (NSWC IHD) E Department has a need to purchase a 3KV Variable Pulser for the purpose of Research Testing Development and Evaluation (RTD&E) Testing. 1) One 3KV Variable Pulser unit with an operating voltage discharge range between 1500V and 3000V 2) Arming and disarming the unit from the front panel. The unit may be manually fired from the front panel, or from a low voltage (+5V) rising edge trigger supplied to the front panel, or a high voltage (+25V to +185V) rising edge trigger supplied to the back panel. Load testing can be done right up until immediately before firing to verify continuity across a bridge wire or initiator from the front panel. Voltage across the output can be monitored from a BNC connector on the front panel. The unit can also be safely and quickly disarmed from the front panel. Operation of the unit is safety controlled with a switch closure interlock through a back panel connector. Power to the unit is switched with a keyed switch. Firing Voltage: Adjustable up to Max KV (3KV) Response Time 850 nanoseconds Jitter ±15ns Polarity Positive, Ground Neutral Trigger Input +5V rising edge (front) +25v to +185V rising edge (rear) Monitoring Voltage monitoring from front BNC connector Optional current monitoring from rear BNC connector Power Input 90-260 VAC 47-63Hz, 300 Watts Cables Includes 75 ft. remote cable HVDC Digi-Key # 97-4102A-18-4P high-voltage pulse discharge connector Other Ability to support a remote control cable length of 500 feet CLAUSES: 52.204-24; 52.204-25; 52.204-26; 52.204-2; 52.204-3; 52.204-7; 52.204-13; 52.204-19; 52.209-10; 52.211-17; 52.219-1; 52.219-28; 52.222-19; 52.222-21; 52.222-26; 52.222-50; 52.223-18; 52.225-13; 52.225-18; 52.232-1; 52.232-8; 52.232-39; 52.232-40; 52.233-1; 52.233-3; 52.233-4; 52.213-1; 52.217-17; 52.247-34; 52.249-1; 52.249-4; 52.252-1; 52.252-2; 252.203-7000; 252.203- 7002; 252.203-7005; 252.204-7003; 252.204-7008; 252.204-7009; 252.204- 7012; 252-204-7015; 252.211-7003; 252.225-7001; 252.225-7048; 252.232- 7003; 252.232-7006; 252.232-7010; 252.243-7001; 252.244-7000; 252.247-7023