Flood Lights FFP - These towers must be diesel powered with a 6KW generator. - Each tower will have four (4) fully adjustable 480 watt LED floodlights. - The mast tower will telescope to 30 feet and r...
Flood Lights FFP - These towers must be diesel powered with a 6KW generator. - Each tower will have four (4) fully adjustable 480 watt LED floodlights. - The mast tower will telescope to 30 feet and rotate 360 degrees by way of dual hand operated winches. - The diesel engine will operate at a minimum of 1800 RMP and the power a brushless four pole generator. - The diesel fuel tank capacity will be a minimum of 30 gallons and the fuel consumption will not exceed 0.4 gallons per hour. - Four (4) 120V AC duplex GFCI outlets are required. - The system will include a 12V Group 24 starting battery. - The trailer will utilize leaf spring axles. - Powder coated gull wing doors, and a hinged top access panel will be included on the housing of the unit. - A combination 2.5 inch pintle hook and 2 inch ball hitch must be included. - The unit will include fuel, temperature, and oil gauges. - Automatic engine shutdown must be included. - Push button start and stop switch with an external emergency shut off button must be included. - Delivery form DD250, Operator, parts and service manuals will be included.