Pilot Valve Test Stand Parts
Commodity Synopsis: The US Air Force (USAF) intends to solicit and issue one contract for the following commodities: The 76th AMXG requires a contract for the purchase and delivery of Pilot Valve Test... Commodity Synopsis: The US Air Force (USAF) intends to solicit and issue one contract for the following commodities: The 76th AMXG requires a contract for the purchase and delivery of Pilot Valve Test Stand Parts. This requirement must have the following specifications: Two (2) Thermowells •Shall have ½” NPT male threaded mount type •Shall have 304 stainless steel •Shall have 200F maximum temperature •Shall have 7,000 psi maximum pressure •Shall have Thermometer with 4” stem length, ¼” stem diameter, and ½” NPT male. Two (2) Resistance Temperature Detectors •Shall have 100 ohm RTD •Shall have a Temperature range 0 to 200F •Shall have a 4” probe length •Shall have a ¼” diameter •Shall have a + 0.1% accuracy •Shall have a ½” NPT male probe connection •Shall have a 10, 30 DC Voltage •Shall have a Analog 4-20mA output Two (2) Air Bleed Valves •Shall have a 400 bar pressure rating •Shall have a Opening pressure 0.05 bar •Shall have a Closing pressure > 0.5 bar Six (6) Pressure Transducers •Shall have 0 to 7,500 psi pressure range •Shall have + 0.25% accuracy •Shall have Analog 4-20mA output •Shall have ¼” NPT male pressure port •Shall have Cable connection •Shall have -40 to 185 F temperature range Two (2) Flow Meters •Shall have 0.003 to 0.8 GPM flow range •Shall have + 0.5% accuracy •Shall have Analog 4-20mA output •Shall have 5,000 psi maximum operating pressure •Shall have 400F maximum process temperature •Shall have 303 stainless material •Shall have ¼” NPT female process connection •10 to 28 Vdc supply power Six (6) Adjustable Pressure Relief Valves •Shall have 3/8” Medium Pressure tube fitting inlet •Shall have ¾” NPT female outlet fitting •Shall have 1,000 to 10,000 psig adjustable pressure range Nine (9) Air Actuated Valves •Shall have 1/8” NPT female end connections •Shall have 1.2 Cv flow coefficient •Shall have 316 stainless steel •Shall have 10,000 psig at 100 F pressure rating •Shall have PEEK seats •Shall be Operated by shop air at 75 – 90 psig •Shall have Mounting flanges for mounting air actuated valve Four (4) Check Valves •Shall have ¾” NPT female end connections •Shall have 2.9 Cv flow coefficient •Shall have minimum10,000 psig pressure rating •Shall have 316 stainless steel Twelve (12) Pipe Nipples •Shall have 316 stainless steel •Shall have (min or Max??) 7,300 psi pressure ratings •Shall have ¾” NPT Male connections •Shall have a Hex flats body shape Eleven (11) Solenoids •Shall be able to use with compressed air •Shall be Normally closed •Shall have a 3/2 flow pattern •Shall have single acting spring return •Shall have 3 flow ports •Shall have 1 inlet •Shall have 1 outlet •Shall have 1 exhaust •Shall have 1/8” NPT female inlet/outlet connections •Shall have 0 to 120 psig pressure range •Shall have Power consumption of < 7W •Shall have 24V DC •Shall have 2 wire lead wire connections •Shall have Mounting holes Twenty Two (22) Push to Connect Fittings •Shall have Straight fitting •Shall have integrated shut-off •Shall be for use with air •Shall have Tube push to connect connections style •Shall have ¼” tube outer diameter •Shall have Pipe connection of 1/8” NPT male •Shall have 140 psig maximum pressure rating •Shall have a 32F to 140F temperature rating Two (2) Right Angle Flow Manifolds •Shall be for use with air •Shall have 2 inlets •Shall have 12 outlets •Shall have ¼” NPT female inlets •Shall have 1/8” NPT female outlets •Shall have Outlet center to center spacing > 1.5” •Shall have minimum 1,000 psig pressure rating Two (2) Tubings •Shall be for use with air •Shall be made of Polyurethane Rubber material •Shall have 95A Durometer •Shall be Opaque •Shall have Inner diameter of 1/8” •Shall have Outer diameter of ¼” •Shall have Wall thickness of 1/16” •Shall have a Bend radius of ½” •Shall have -40 to 160F temperature range •Shall have 260 psig maximum pressure rating •Shall be the color blue Fourteen (14) Manual Valves •Shall be for use with hydraulic fluid •Shall have On/Off style valve •Shall have Manual actuation •Shall have 1/8” NPT female inlet/outlet connection •Shall have a 1 gpm maximum flow rate •Shall have a 7,200 psig maximum pressure rating •Shall have 0 to 212 F temperature range •Shall have a Ball type valve Two (2) High Pressure Manifolds •Shall have a 10,000 psi maximum pressure rating •Shall have 2 inlet ¼” NPT female •Shall have 8 outlet connections 1/8” NPT female •Shall have an Outlet connection spacing > 1.25” Fourteen (14) Hydraulic Gages •Shall be for use with hydraulic fluid •Shall have a 0 to 6,000 psig pressure range •Shall have + 2% accuracy •Shall have ¼” NPT male connection •Shall have 304 stainless steel •Shall have Dial diameter of 2.5” or less •Shall have Graduation marks 100 psi •Shall have Numeric increments of 1,000 Nine (9) Street Elbows •Shall have a 4,600 psig pressure rating •Shall be 316 stainless •Shall be ¾” NPT female x ¾” NPT male •Shall have 90 degree elbow Two (2) Benchtop power Supplies •Shall have an Input with: Voltage 120/240 VAC, Current 20 A at 120 V AC,Frequency 50/60 Hz, and Three prong plug •Shall have an Output with: 1 – 30 VDC adjustable, 30 A, Power 30 – 900 W, Frontauxiliary output, 1 – 30 VDC, 1 – 5 A, and Digital display for output One (1) AC Power Source •Shall have Maximum AC output power 2,000 VA •Shall have Maximum AC output current 20A •Shall have AC output voltage range 155 Vrms •Shall have Voltage setting accuracy 0.35% full scale •Shall have Maximum DC output current 16A •Shall have Maximum DC power capacity 1600 W •Shall have DC output voltage range 219V •Shall have Voltage setting accuracy 0.3% full scale •Shall Measure voltage, current, power, AC, and DC •Shall be LAN capable ethernet I/O •Shall have a USB Two (2) Variable-Voltage Transformers •Shall have AC to AC transformer type •Shall have Step down transformer •Shall be Single phase •Shall have Input voltage 120V AC •Shall have Output voltage 0 – 120 V AC •Shall have Power output 1,800 VA •Shall have a Maximum current of 15 A One (1) Hydraulic Power Unit •Shall have Maximum Operating Pressure (psi) of 10,000 •Shall have Cylinder Compatability, Double-acting •Shall have Reservoir Capacity (in3) of 2,379 •Shall have Usable Oil Capacity (gal)of 10 •Shall have Maximum Flow at Rated Pressure of 120 in3/min •Shall have Output Flow Rate (in3/min) 100 psi of 850 •Shall have Output Flow Rate (in3/min) 700 psi of 825 •Shall have Output Flow Rate (in3/min) 5000 psi of 123 •Shall have Output Flow Rate (in3/min) 10000 psi of 120 •Shall have Motor Size (hp) of 3 •Shall have Motor Size (rpm) of 1,750 •Shall have Motor Hertz of 50/60 Hz •Shall have Motor Phases, 3 Ph •Shall have Motor Voltage of 208-240 V •Shall have Duty Cycle, Extended •Shall have Valve Function of Advance / Hold / Retract •Shall have Valve Operation of Solenoid •Shall have Solenoid Valve Voltage of 24 VDC •Shall have Valve Type with 4-way, 3-position, Tandem Center •Shall have Valve Model of VE43 •Shall have Power Source, Electric •Shall have Pump Control, Pendant •Shall have Motor Electrical Specification of 208-240 V, 3 Ph, 50/60 Hz •Shall have a maximum Sound Level (dBa) of 75 •Shall have Relief Valve Adjustment Range (psi) of 1,000 - 10,000 A Firm Fixed Price (FFP) contract is contemplated. Estimated Period of Performance: 89 Days ARO. System for Award Management (SAM) is required to receive any award. Contractors can register electronically at https://www.sam.gov/portal/public/SAM/ . The NAICS code for this requirement is 334515, with a size standard of 750 EMP. Interested persons may identify their interest and capability to respond to the requirement by submitting a proposal. Electronic procedures will be used for this solicitation through beta.Sam.gov at https://beta.SAM.gov/. No telephone requests. See Note 22. Authority is 10 USC 2304 (c) (1). For further information contact: Patricia A. Johnson, Contracting Specialist patricia.johnson.27@us.af.mil
Data sourced from SAM.gov.
View Official Posting »