Inactive
Notice ID:FA5270-Q-Incubators
Four Neonatal Incubators with the following Characteristics: * Full Color Touch Display: 10.4 in (26.4cm) LCD * External mattress tilt control * Mattress tilt angle: 12, &continuously variable * Micro...
Four Neonatal Incubators with the following Characteristics: * Full Color Touch Display: 10.4 in (26.4cm) LCD * External mattress tilt control * Mattress tilt angle: 12, &continuously variable * Micro filter: 0.5µ -99.8% efficiency (3M FiltreteTM) * Tubing access ports: 8 * Double walled incubator * Overhead canopy to convert to a warmer * Server Control range: * 21% to 65% * Display range: 16 to 70% * Rise Time: < 10 minutes from 5% below set point in Whisper Quiet Mode after open door * Recovery from opening porthole: ? 5 minutes from closing porthole to 5% below set point * Alarms: ±3% from set point * Humidifier performance: * Recovery time: < 15 minutes (typical) Recovery to 75% RH with 39°C air set temperature * Operating time between refills: > 12 hours @ 65% RH control setting in a 25°C/50% RH ambient * Reservoir capacity: 1000 ml * Servo Control Accuracy: ±10% for settings up to 85%: minimum 75% for settings > 85% * Ramp-up time: ? 50 minutes - Time to reach 75% RH with a 39°C control temp from cold start in 25° C, 50% RH room. * Operating Environment * Temperature: 20° to 30°C * Air boost button * Humidity: * 5 to 85% RH (non-condensing) * Air Velocity: Up to 0.3m/sec * Water Ingress: IPXO * In bed scale: * Accuracy: ±0.35oz (10g) * Range: 0.66lbs. to 17.6lb. (300g to 8kg) * Characteristics: * Full Color Touch Display: 10.4 in (26.4cm) LCD * External mattress tilt control * Mattress tilt angle: 12, &continuously variable * Micro filter: 0.5µ -99.8% efficiency (3M FiltreteTM) * Tubing access ports: 8 * Double walled incubator * Overhead canopy to convert to a warmer * Servo Control range: * 21% to 65% * Display range: 16 to 70% * Rise Time: < 10 minutes from 5% below set point in Whisper Quiet Mode after open door * Recovery from opening porthole: ? 5 minutes from closing porthole to 5% below set point * Alarms: ±3% from set point * Humidifier performance: * Recovery time: < 15 minutes (typical) Recovery to 75% RH with 39°C air set temperature * Operating time between refills: > 12 hours @ 65% RH control setting in a 25°C/50% RH ambient * Reservoir capacity: 1000 ml * Servo Control Accuracy: ±10% for settings up to 85%: minimum 75% for settings > 85% * Ramp-up time: ? 50 minutes - Time to reach 75% RH with a 39°C control temp from cold start in 25° C, 50% RH room. * Operating Environment * Temperature: 20° to 30°C * Air boost * Humidity: * 5 to 85% RH (non-condensing) * Air Velocity: Up to 0.3m/sec * Water Ingress: IPXO * In bed scale: * Accuracy: ±0.35oz (10g) * Range: 0.66lbs. to 17.6lb. (300g to 8kg)