Inactive
Total Small Business Set-Aside (FAR 19.5)
Notice ID:FA524024QM089
See attachments for additional details. 6/24/24: AMENDMENT 0001 The purpose of this amendment is to provide responses to Requests For Information received. Q1: What is the outlet pressure requirement ...
See attachments for additional details. 6/24/24: AMENDMENT 0001 The purpose of this amendment is to provide responses to Requests For Information received. Q1: What is the outlet pressure requirement for the blower? A1: According to TO 36G2-3-1, para 1.2.2.1 Blower. The blower is a rotary positive displacement unit which utilizes a 3-lobe rotor design. It is capable of delivering oil-free air to the heater assembly at a rate of 6 Pounds Per Minute (PM). Blower end plates are drilled to allow free flow of lubrication between bearings and seals without contaminating the air being delivered. Q2: Would a different type of blower be acceptable if able to meet the performance requirements? A2: As long as all performance requirements are met. Q3: What power is available to run the cart? What type of receptacle? A3: 220 Volt. There are 2 receptacle ports (see photos). Q4: What type of end connections are needed for the adapters? A4: The servicing hose is 10 feet long and is covered by a scuff resistant jacket. The inside diameter of the hose is 1-1/4 inch. The free end of the hose contains a quick disconnect coupling which fits any of the three adapters employed. The three adapters are 1inch ips, 1-1/2 inch ips, and 2 inch ips. Attachments added: Attachment 3 - TO 36G2-3-1 Attachment 4 - RFI Q3 Photos