Generator Surge Suppression
This announcement constitutes a Sources Sought Synopsis (market survey). This is not a request for quote (RFQ) or a request for proposal (RFP). This announcement is for information and planning purpos... This announcement constitutes a Sources Sought Synopsis (market survey). This is not a request for quote (RFQ) or a request for proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The Government will not pay for any cost incurred in responding to this announcement. Any information submitted by respondents to this Sources Sought synopsis shall be voluntary. This Sources Sought Notice is for Market Research purposes only. The information submitted in response to the Sources Sought Notice will not be utilized to determine vendor standing in any future/potential Request for Quote/Request for Proposal, nor will it be utilized to determine if a vendor is qualified to submit a Request for Quote/Request for Proposal for any future/potential requirement. The notice and the information received shall not be used to determine how well respondents can perform a requirement, which can only be evaluated in response to a solicitation. Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought request. All future/proposed submissions/solicitations requirements solicited on a Government Point of Entry will be evaluated independent of any information submitted in response to this Sources Sought Notice. No vendor will be provided information on solicitations issued on a Government Point of Entry based on this Sources Sought request. This Sources Sought Notice is relative to the NAICS code 335931. The Small Business size standard for this NAICS code is 500. Large and Small Businesses are invited to answer this market survey to determine market capabilities. Hurlburt Field, FL, is conducting market research to determine the existence of potential sources to provide Backup Generators (Surge Suppression Devices) The potential requirement will consist of the contractor providing brand name or equal: Surge Suppression Incorporated (SSI) Surge Suppression Systems CLIN QTY DESCRIPTION 0001 99 SSI Surge Suppression System 120/208V 3 Phase Wye (4 wire + ground), Part #LSEB3Y1X3-36IN Peak Surge Current: 80kA(L-N,L-L,L-G,N-G), 800kA total. MCOV: 150V (L-N,L-G,N-G) 300V (L-L) Type 2 SPD, In= 20kA 0002 63 SSI Surge Suppression System 277/480V 3 Phase Wye (4 wire + ground), Part #LSEB3Y2X3-36IN Peak Surge Current: 80kA(L-N,L-L,L-G,N-G), 800kA total. MCOV: 320V (L-N,L-G,N-G) 550V (L-L) Type 2 SPD, In= 20kA 0003 2 SSI Surge Suppression System 120/240V 1 Phase Split (3 wire + ground), Part #LSEB1S1X3-36IN Peak Surge Current: 80kA(L-N,L-L,L-G,N-G), 480kA total. MCOV: 150V (L-N,L-G,N-G) 300V (L-L) Type 2 SPD, In= 20kA 0004 157 SSI Surge Suppression System Part #TC24D4-B 24V Maximum Continuous Operating Voltages: 38VDC Maximum Continuous Operating Current: 5A B3/C1 Impulse Wave 6kV 3kA (100Kbps): 220 (T/R-G,T-R) Salient Characteristics: ANSI/IEEE C62.41.1 & C62.41.2-2002 environments: Suitable for Categories: A, B & C (Most Severe Electrical Environments) IEC Environments: Suitable for use in IEC 61643-11 environments Protection Modes: Protection components for all operational modes of the electrical system. Discrete L-N, L-L (Normal Mode) and L-G, N-G (Common Mode) Input Power: 50-400 Hz (60 Hz nominal) Temperature Rating: Up to 80°C Standard Enclosure: NEMA 1 Rated Standard Enclosure NEMA 4X Composite Enclosure (10"x8"x4") Nominal Discharge Current (In) Rating: 10 kA (LSEC, LSEA), 20 kA (LSEB, LSED**) (**Complies with the requirements of UL 96A Master Label for Installation Requirements for Lightning Protection Systems) Diagnostics: Green LED's, one per phase, normally on. Circuit Interrupt: Internal component-level, thermal fusing and patented circuit board mounted, over-current fusing. No external over-current protection required. Note: National and local codes may require the use of a circuit interrupt device(s) if conduit is added to make the wired connection to the panel or gear. Insertion Loss Data: (L-N) Frequency: 280kHz 1MHz Max Attenuation & Freq. Attenuation: 3dB 17dB 40dB @ 483kHz Standard Enclosure: NEMA 1 Rated Standard Enclosure Nominal Discharge Current (In) Rating: 10kA (LSEC, LSEA), 20 kA (LSEB, LSED) Diagnostics: Green LED's, one per phase, normally on. Circuit Interrupt: Internal component-level, thermal fusing and circuit board mounted, over-current fusing. No external over-current protection required. Short Circuit Current Rating: 200 kAIC Product Qualifications: Listed to ANSI/UL 1449 by UL (E340498), CSA (MC#241804); UL1283. ISO 9001 Certified Manufacturing Facility by NQA NOTE: Please submit an electronic response indicating capability to supply the aforementioned item(s) via line card or published description (no more than 3 pages) as well as POC (name, telephone # and email address) along with contractor's CAGE, DUNS, and the physical location of your facility to the individuals listed within this notice. All work shall be performed at the contractor's facility. This request may not directly lead to a Request for Quotation/Proposal. Required Information: Any interested party who can offer all of the above may submit a written reply of not more than 3 pages, addressing each of the above items and defining how their location is capable of ALL of the minimum requirements listed above.
Links ()
Attachments ()
Data sourced from SAM.gov.
View Official Posting »