2 Door(s) - STC 51 rated Doors – Thickness 2-1/2”, Width 3’ 4-1/4”, Height 7’-2” White Finish – Remove and install doors squarely within their respective frames 2 Accessory(s) Von Duprin EPT 10 Power ...
2 Door(s) - STC 51 rated Doors – Thickness 2-1/2”, Width 3’ 4-1/4”, Height 7’-2” White Finish – Remove and install doors squarely within their respective frames 2 Accessory(s) Von Duprin EPT 10 Power Transfer Switches BMS Magnetic Switch 2 Door Closers and Coordinators – Install on the two sets of emergency exit doors, one pair in B4625 and one in B4626 2 Hinges - Set(s) Cam-Lift Hinges replacement. Conduct sound testing and provide sound test report subsequent to installation 1 Structural Diagonal Bracing – Install on strike side of door existing truss or rafter above 1 Structural Bracing – Install above existing acoustical ceiling and securely fastened at each end 1 Seals - Set(s) Remove and replace Self aligning magnetic perimeter seals and concealed bottom seal 1 Hardware - All - Hardware to be included in the scope of supply as well as all pertinent hardware to ensure proper fit, finish, and function. 2 Alarm – Remove existing surface mounted panic hardware on a pair of emergency exit doors in both B4625 and B4626 and replace with self-contained automatic alarming panic hardware. Alarm should sound automatically upon pushing the panic bar on either the active or inactive leaf of double doors 1 Debris – Dispose any debris generated throughout the work and clean the areas of the facilities where work was performed to original coordination 2 Sill Plate 1/4" thick aluminum sill plate(s) to be included