Inactive
Notice ID:1161A001
The contractor shall provide a 12’ x 12’ Radio Frequency (RF) shield enclosure connecter panel with specified connectors for a Series 81 shield enclosure installed by ETS-Lindgren. The shielding perfo...
The contractor shall provide a 12’ x 12’ Radio Frequency (RF) shield enclosure connecter panel with specified connectors for a Series 81 shield enclosure installed by ETS-Lindgren. The shielding performance will provide isolation against the following frequencies: Magnetic Field (18 dB @ 1 kHz/50 dB @ 14 kHz), Electric Field (100 dB from 14 kHz – 10 MHz), Plane Wave (100 dB from 10 MHz – 1GHz), and Microwave (100 dB from 1 – 10GHz). For the design and shield acceptance testing, the shield verification test will meet in general accordance of the test methods of Military Standard (MIL-STD) MIL-STD-285 / Institute of Electrical and Electronic Engineers (IEEE) IEEE-299 at 1 GHz plane wave field.