National Oceanic and Atmospheric Administration’s (NOAA) Office of National Marine Sanctuaries (ONMS), West Coast Regional Office (WCRO) in Monterey, California requires the removal and replacement of...
National Oceanic and Atmospheric Administration’s (NOAA) Office of National Marine Sanctuaries (ONMS), West Coast Regional Office (WCRO) in Monterey, California requires the removal and replacement of two 20kW marine diesel electrical generators and associated improvements to the electrical system for the 67’ R/V Fulmar located in Monterey, CA, The existing electrical generators have reached end of life. Furnish all labor, equipment, parts, cables, controllers and other materials to remove and replace the existing Kohler 20kW marine diesel electrical generators with two new 20kW marine diesel electrical generators. Revise electrical system on the vessel. All fasteners shall be stainless steel and the use of dissimilar metals shall be avoided unless separated by nylon washers. All connectors and connections shall be appropriate for service in the harsh marine environment. All cable penetrations shall be filled with USCG approved water-tight sealant. PLEASE SEE STATEMENT OF NEED FOR MORE DETAILED SPECIFICATIONS.